Safe and simple sampling of gaseous media

Type GSP / Type LGSP

  • for gasous media and liquid gas
  • sampling volume per operation: 150 / 300 / 500 cm³
  • safe and contamination-free

PN 10 – 100
Class 150 – 600

Ventilation: internally back to system

Sichere und einfache Probenahme gasförmiger Medien Typ GSP / Typ LGSP

Safe and simple sampling of gaseous media

Type GSP / Type LGSP

Sichere und einfache Probenahme gasförmiger Medien Typ GSP / Typ LGSP
  • for gasous media and liquid gas
  • sampling volume per operation: 150 / 300 / 500 cm³
  • safe and contamination-free

PN 10 – 100
Class 150 – 600

Ventilation: internally back to system

Design characteristics

  • closed system
  • representative, contamination free sample
  • defined sampling quantity
  • integrated system purge
  • all components mounted on ready-to-install stainless steel plate
  • bypass assembly

Options

  • protection box (lockable, heatable)

Material

  • valves, pipes and pressure cylinder made of stainless steel, other on request

Approvals

Pressure cylinder acc. to TPED (Transportable Pressure Equipment Directive) or DOT (US Department of Transportation)

Design characteristics

  • closed system
  • representative, contamination free sample
  • defined sampling quantity
  • integrated system purge
  • all components mounted on ready-to-install stainless steel plate
  • bypass assembly

Options

  • protection box (lockable, heatable)

Material

  • valves, pipes and pressure cylinder made of stainless steel, other on request

Approvals

Pressure cylinder acc. to TPED (Transportable Pressure Equipment Directive) or DOT (US Department of Transportation)

Variants

Type GSP

Typ GSP für Gas-Probenahmen (Probebehälter auf Bedientafel)

Gas sampling system
(sampling cylinder at control panel)

Type LGSP

Typ LGSP für Flüssiggas- Probenahmen (externer Probebehälter)

Liquid gas sampling system
(sampling container outsite of the control panel)

Standard sample cylinder for gas and liquid gas

Typ GSP für Gas-Probenahmen (Probebehälter auf Bedientafel)
  • cylinder volume 150, 300 or 500 cm3, other on request
  • material for cylinder, couplings and connections in Stainless steel (304L or 316L), other on request
  • different pressure ratings, depending on the material and temperatur load in the system or from media
  • cylinder according TPED or other on request

Recommendation for filling for media: gas

Typ GSP für Gas-Probenahmen (Probebehälter auf Bedientafel)
  • fill gaseous media from top to bottom (to remove condensate)
  • any increase in volume or pressure at ambient temperatures must be taken into account when calculating the necessary pressure rating of system or cylinder

Recommendation for filling for media: liquid gas

Typ GSP für Gas-Probenahmen (Probebehälter auf Bedientafel)
  • fill liquid gas from bottom to top (to discharge gases)

filling pipe (length determines the size of the vapor volume)

vapor space

sampling volume

cylinder volume = sampling volume + vapor space

Variants

Functionality: Gas sample drawing with GSP

  • the flushing of the complete, closed system incl. cylinderensures optimal collection of a representative, contamination-free sample
  • safe sample drawing (leakage free / self-closing) with only one handwheel
  • sampling cylinder can easily be removed by quick couplings and contamination-free sample quantity

Design for continuous flow when not in use with three interconnected 3-way plug valves

Type GSL-3 (gas)
Type LGSP-3 (liquid gas)

  • Example LGSP-3

Design for temporary flow with two interconnected 3-way plug valves type GSL-2 (gas) type LGSP-2 (Flüssiggase)

Type GSL-2 (gas)
Type LGSP-2 (liquid gas)

  • Example GSP-2

Example for sampling drawing with LGSP-3

1. Basic position

Handwheel position PROCESS (0°)

  • no-flow through system
  • inserting of sample container
  • open cylinder, shut-off valves (A)

Process out

Process in

Slop (vent)

2. System purge

Handwheel position SPURGE (180°)

  • purge system for a few minutes

Process out

Process in

Slop (vent)

3. Closing

Handwheel Position CLOSE (90°)

  • system isolated from process
  • media contained
  • sampling cylinder filled
  • close cylinder, shut-off valves (A)

Process out

Process in

Slop (vent)

4. Depressurization & removal

Handwheel position PROCESS (0°)

  • no-flow through system
  • depressurizatin of system via slop/flame
  • open quick connects (B)
  • remove sample cylinder

Process out

Process in

Slop (vent)

AZ Armaturen Engineering