Sample drawing without flow interruption
Type CONTIFLOW
for liquids and solids-containing media
Sampling volume / operation:
VPmin 25 ml / VP max 100 ml
Bottle volume VF min 50 ml / VF max 2000 ml
- safe and simple operation
- emission-free
- piggable
DN 15 – 200 / PN 10 – 40
NPS ½ – 8 / Class 150 – 300
Sample drawing without flow interruption
Type CONTIFLOW
for liquids and solids-containing media
Sampling volume / operation:
VPmin 25 ml / VP max 100 ml
Bottle volume VF min 50 ml / VF max 2000 ml
- safe and simple operation
- emission-free
- piggable
DN 15 – 200 / PN 10 – 40
NPS ½ – 8 / Class 150 – 300
Sealing systems
Design characteristics
- safe sample drawing – pressureless
- representative sample, defined volume
- individual bottle connections
Options
- closed needle system
- heating jacket
- air-evacuation device
- purge device
- fully PFA / FEP / PTFE lined design
Safe sample drawing
- pressure-free sampling for incompressible media
- isolated from the product flow (positive overlap)
- spillage-free sampling with individual bottle connections (option)
Representative sample
- directly from main product flow, no flow interruption
- no contamination or sediment due to the cavity-free design
Emission-free
- closed system
- product flow never exposed to atmosphere
- integrated ventilation into system during sample release (optional)
Easy operation
- no failures due to single lever operation and position indicator
- operation with
- hand lever
- actuator / gearbox 180°
Sealing systems
Design characteristics
- safe sample drawing – pressureless
- representative sample, defined volume
- individual bottle connections
Options
- closed needle system
- heating jacket
- air-evacuation device
- purge device
- fully PFA / FEP / PTFE lined design
Safe sample drawing
- pressure-free sampling for incompressible media
- isolated from the product flow (positive overlap)
- spillage-free sampling with individual bottle connections (option)
Representative sample
- directly from main product flow, no flow interruption
- no contamination or sediment due to the cavity-free design
Emission-free
- closed system
- product flow never exposed to atmosphere
- integrated ventilation into system during sample release (optional)
Easy operation
- no failures due to single lever operation and position indicator
- operation with
- hand lever
- actuator / gearbox 180°
Functionality
Media flow,
standard position
Pos 1
0°
Filling the plug,
defined volume
Pos 2
180°
Isolation of sample
– pressure-free !
Pos. 3
90°
Sample drawing
Pos. 4
0°
Variants
Type Contiflow
metallic with PTFE sleeve
T -60 < T < 250°C
Pmin vacuum-capable
Vmax 50 bar
Installation positions Type Contiflow
Type Contiflow
Standard
Type Contiflow-W
Horizontal
Type Contiflow-V
Vertical
Typ Contiflow-AB /Contiflow-A
Contiflow-AB
Based on type CONTIFLOW-A & exchangeable PTFE sleeve
- reduced torque
- repairable
- higher temperature resistance
- sustainable solution
T -10 < T < 210°C
Pmin vacuum-capable
Pmax 25 bar
Repair kit for CONTIFLOW-AB
consisting of
- lined plug
- PTFE sleeve
- cover / stem sealing
Typ Contiflow-AB
Contiflow-A
Body and plug with PFA lining
T -10 < T < 150°C
Pmin vacuum-capable
Pmax 25 bar
Typ Contiflow-A
Air-evacuation Type Contiflow-EV
Drawing vacuum from plug volume directly before sample drawing
- locking pin ensures vacuum position
- direction of rotation only counterclockwise
Purge device Type Contiflow-SP
Purging of plug, needle system and lab bottle with Nitrogen N2 or steam
- locking pin ensures purging position
- OPEN/CLOSE of purging line by plug (no additional valve necessary)
Contiflow Accessories
Increased sample volume
Increase of sample volume VP by additional, modular adapter (standard installation position)
- plug volume VP
- 75 ml
- 100 ml
- (standard plug 25/50 ml)
- modular design
Option: VP
Heating / cooling jacket
- solid cast full heating jacket, flange to flange
- heated cover seat
- different connections for heating medium
- flanges
- threaded
- welding ends
Cleaning in Place – CIP
- CIP-compliant
- with PTFE/PFA lined plug
- without sleeve, gapless
- for pharmaceutical applications
Protection box
Types
- for the whole sampling valve
- with ventilation, exhaust
- lockable
- heatable / coolable
- with lighting
- detection of bottles, filling level etc.
Protection box combination
Integrated control cabinet for automated sampling
- individual setting of time period, sampling cycle, volume
- sensors monitoring the sampling operation
- standard interface for actuator, sensor, pneumatic
ATEX optional
Type CONTIFLOW-PLC-II
fully automated sampling – easily programmable controller
Sampling protection box combination with integrated control box for advanced functions, e.g.
- runtime error
- sampling interruption
- collective fault signal
Process of the sampling
- Insert empty or partly filled bottle, close door
- The bottle is lifted pneumatically
- Automated sampling system
- Indication after termination of program (no overfilling of bottle due to sensor)